2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 462


Test sequence



- Switch off ignition.



- Connect socket box (126-pin) to component N3/10 (ME-SFI [ME] control unit).



- Measure resistance with multimeter between sockets [M.26] 26 and [F.3] 99 of the 126-pole socket box tester.



Specified value



- Resistor[11...17]ohms



Question



- Is the measurement value OK?



YES



The measurement value is OK.Note



- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose



contact and corrosion..



NO



The measurement value is not OK.Test sequence



- Switch off ignition.



- Connect shop-made test cable set to component Y62y5 (Fuel injector cylinder 5).



- Measure resistance with multimeter between pins (Y62) 1 and (Y62) 2



Specified value



- Resistor[11...13]ohms



Question



- Is the measurement value OK?



YES



The measurement value is OK.Possible cause and remedy



- Lines to component Y62y5 (Fuel injector cylinder 5)



NO



The measurement value is not OK.Possible cause and remedy