Question
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- N10/1f52 (Fuse 52)
- Lines
End of test
Part 2
A/C compressor2 : CAN transmission error of signal from component AC compressor ( Toggle error / Parity error )
1.1.3.2.1.2. Check power supply at control unit N15/3 (ETC [EGS] control unit).
Test 1.1.3.2.1.2.1: Guided test
1.1.3.2.1.2.1. Guided test
Operation number of operation texts and work units or standard texts and flat rates:27-0641Possible cause
- Battery has incorrect charge state or is faulty.
- Local undervoltage of component N15/3 (ETC [EGS] control unit)
Test sequence
- Erase fault memory.
Continue with button "F2"
Warning!Communication with ECU required.
1.1.3.2.1.3. Check power supply at control unit N15/5 (Electronic selector lever module control unit).
Operation number of operation texts and work units or standard texts and flat rates:27-0641Test sequence
- Switch off ignition.
- Disconnect connector at component N15/5 (Electronic selector lever module control unit).
- Switch on ignition.
- [A.2] Measure direct voltage with multimeter between 2 and 1 [A.1]
Status of relevant actual value:
- Supply voltage (tml. 15):Warning! Communication with ECU required.
Specified value
- Voltage[7.0...16.0] V
Question
- Is the measurement value OK?
YES
The measurement value is OK.Possible cause and remedy