- X63/4 (CAN databus adapter connector, 2-pin)
- Test connectors and wiring for CAN of engine compartment CAN control modules.
- Control unit
Communication with ECU required ( Measuring system )
E0562
The voltage supply of circuit 87 has undervoltage.
Possible cause:
- Local undervoltage of component Y3/8n4 (Fully integrated transmission control (VGS) control unit)
Affected functions:
- Battery / On-board electrical system
- CAN Communication
- Automatic transmission Function
-------------------------------------------------
Test 1: Check power supply at control unit Y3/8n4 (Fully integrated transmission control (VGS) control unit).
1. Check power supply at control unit Y3/8n4 (Fully integrated transmission control (VGS) control unit).
Operation number of operation texts and work units or standard texts and flat rates:27-0641Test sequence
- Switch off ignition.
- Separate plug connection at transmission.
- Measure voltage in transmission wiring harness using a multimeter.
- Switch on ignition.
Measure direct voltage with multimeter between 5 and 4Specified value:
- Voltage[8,5...16,4] V
Question
- Is the measurement value OK?
YES
The measurement value is OK.Possible cause of fault
- The conductors in the electrohydraulic control unit are interrupted.
- Component Y3/8n4 (Fully integrated transmission control (VGS) control unit) is defective.