Thursday, February 11, 2021

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 1749


YES



Note



- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose



contact and corrosion..



End of test



NO



The measured value is not within the specified value range.Possible cause and remedy



- Cables between component N10/1 (Driver-side SAM control unit with fuse and relay module) and control module N63/1 (DTR control



module)5A



- Cable for voltage supply



1.1.3.2.1.13. Check power supply at control unit Y3/8n4 (Fully integrated transmission control (VGS) control unit).



Operation number of operation texts and work units or standard texts and flat rates:27-0641Test prerequisite



- Battery voltage is OK.



- Fuse N10/1f46 (Fuse 46) in component N10/1 (Driver-side SAM control unit with fuse and relay module) is o.k.



Test sequence



- Switch off ignition.



- Separate plug connection at transmission.



- Measure voltage in transmission wiring harness using a multimeter.



- Switch on ignition.



Measure direct voltage with multimeter between 5 and 4Specified value



- Voltage [8,5...16,4] V



Question



- Is the measurement value OK?