YES
The latching is OK.Possible cause and remedy
- Replace PremAir sensor.
- The PremAir sensor must be installed and bonded in the second hole after being turned 180锟斤拷.
Note
- When the PremAir sensor is replaced the control unit log must also be sent in for warranty processing.
End of test
NO
The latching is not OK.Possible cause and remedy
- Check whether a PremAir radiator and PremAir sensor are installed, replace relevant parts if necessary.
End of test
2054
PremAir sensor : Short circuit to ground
Possible cause:
- B11/15 (PremAir sensor)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check component B11/15 (PremAir sensor).
1. Check component B11/15 (PremAir sensor).
Test 1.1: Check attachment and installation location of sensor B11/15 (PremAir sensor).
1.1. Check attachment and installation location of sensor B11/15 (PremAir sensor).
Check attachment and installation location of sensor B11/15 (PremAir sensor).
Test sequence
- Check whether the PremAir sensor is firmly latched and bonded to the PremAir radiator.