1.1.3.4.1.8. Steering column module
Warning!Communication with ECU required.
2. Check component A1 (Instrument cluster).
Read and process fault code from control module A1 (Instrument cluster).
Possible cause and remedy
- Read and process fault code from control module A1 (Instrument cluster).
End of test
2053
PremAir sensor : Short circuit to positive
Possible cause:
- B11/15 (PremAir sensor)
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Check component B11/15 (PremAir sensor).
1. Check component B11/15 (PremAir sensor).
Test 1.1: Check attachment and installation location of sensor B11/15 (PremAir sensor).
1.1. Check attachment and installation location of sensor B11/15 (PremAir sensor).
Check attachment and installation location of sensor B11/15 (PremAir sensor).
Test sequence
- Check whether the PremAir sensor is firmly latched and bonded to the PremAir radiator.
Note
- When the PremAir sensor is removed, it is irreparably damaged and must be replaced.
Question
- Is the PremAir sensor firmly latched and bonded to the radiator?