Sunday, July 12, 2020

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 2557


YES



The measurement value is OK.Possible cause and remedy



- Signal wire



- B11/15 (PremAir sensor)



End of test



NO



The measurement value is not OK.Possible cause and remedy



- N10/1f57 (Fuse 57)



- N10/1kI (Circuit 87 relay, engine)



- Lines to component B11/15 (PremAir sensor)



End of test



1.2. Test signal cable to component B11/15 (PremAir sensor).



Figure legend



- A -ConnectionTest cable 35-pin socket box



- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)



- 05 -35-pin socket box



- 050 -126-pin socket box



- 108 -Test cable 266 589 01 63 00



- N3/10 (ME-SFI [ME] control unit)



- II 1-63ConnectionTest cable



- III 64-126ConnectionTest cable



Warning!



- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).



Continue to test with button F2