Affected functions:
- Automatic transmission Function
-------------------------------------------------
Test 1: Remedial action if component 'Y3/8n4 (Fully integrated transmission control (VGS) control unit)' is faulty
1. Remedial action if component 'Y3/8n4 (Fully integrated transmission control (VGS) control unit)' is faulty
Test prerequisites
- First of all process all other current fault codes.
POSSIBLE CAUSES
- Component Y3/8n4 (Fully integrated transmission control (VGS) control unit) is defective.
Preconditions
- Print out the initial quick test log before processing the fault code 060A.
- Create control unit log.
Important notes before commencing repair measures
- Always use the same diagnostic unit after the repair measure.
Continue with button F2
Sequence
- Data are being read from the old control unit.
Start process with button F2.
1. No further information available.
060C
Component Y3/8n4 (Fully integrated transmission control (VGS) control unit) is defective.
Possible cause:
- Y3/8n4 (Fully integrated transmission control (VGS) control unit)
Affected functions:
- Automatic transmission Function
-------------------------------------------------
Test 1: Remedial action if component 'Y3/8n4 (Fully integrated transmission control (VGS) control unit)' is faulty
1. Remedial action if component 'Y3/8n4 (Fully integrated transmission control (VGS) control unit)' is faulty
Operation number of operation texts and work units or standard texts and flat rates:27-0641Warning!In the event of stored faults with high fault
frequency counter:The control module must not be replaced.Cause
- Control module has an internal error.
REMEDY
- Disassemble and assemble automatic transmission using the repair instructions.
- Exchange electrohydraulic control unit.
Notes on submitting warranty or goodwill claimsSEAG damage code (7 digits): 54553 73IMPORTANT NOTEFollowing the repair measures, the
following checks MUST be carried out using the Diagnosis Assistance System, menu 'Initial startup'
- Initial startup with manual settings input for new control unit
Continue with button "F2"