Monday, June 1, 2020

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 1341


Test prerequisite



- Fault code 'P2281' present



Test sequence



- Measure direct voltage with multimeter between socket [F.4] 100 of the 126-pole socket box tester and socket [F.52] 22 of the 35-pole socket



box tester.



Specified value



- Voltage<1 V



Question



- Is the measurement value OK?



YES



The measurement value is OK.Further possible causes of fault



- Fault in control unit AB: Read out fault memory of control unit N2/7 (Restraint systems control unit).



End of test



NO



The measurement value is not OK.Possible cause and remedy



- Line from component N2/7 (Restraint systems control unit) to component N3/10 (ME-SFI [ME] control unit)



- Read fault memory from control unit AB and rectify faults.



End of test



Part 1



The CAN signal from circuit 15 does not match the signal via the hardware line. ( Signal via CAN = 0 )



Possible cause:



- Drive train CAN bus



Affected functions:



- Power generation



-------------------------------------------------