2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts
none
(DME) Condition For Fault Memory Entry - 1
2CA7 - P0155
Information saved in
DME
Fault code
92
2CA7 - P0155
Fault text
Oxygen sensor heating before catalytic converter 2, function
Fault description
O2 Sensor Heater Circuit (Bank 2 Sensor 1)
Condition for fault identification
Test condition:
Check O2 sensor heater; sensor too cold
Terminal condition: Terminal 15, engine on
Voltage condition:
none
Condition for fault memory entry
O2 sensor temperature < 680 掳C for more than 5 sec.
Action in service
1. Visual inspection of wires, DME plug and O2 sensor for
damage
2. Check wires (including resistance)
3. Check plug-in connections DME <=> Wiring harness
<=> Upstream (pre-cat) O2 sensor for Bank 2 (water or
corrosion in the plug? => Repeatedly disconnect the plug
and then FIRMLY press it back in)
4. Replace O2 sensor
5. Replace DME
Fault effect and breakdown warning
DIAGNOSIS AND REPAIR, MAINTENANCE, PARTS AND LABOR, SHOP OPERATIONS, TECHNICIAN'S REFERENCE, DIAGNOSTIC TROUBLE CODES(dtc), RELAYS AND MODULES, SENSORS AND SWITCHES,ENGINE, COOLING AND EXHAUST, POWERTRAIN MANAGEMENT, TRANSMISSION AND DRIVETRAIN, BRAKES AND TRACTION CONTROL, STARTING AND CHARGING, POWER AND GROUND DISTRIBUTION, STEERING AND SUSPENSION, HEATING AND AIR CONDITIONING, RESTRAINTS AND SAFETY SYSTEMS, ACCESSORIES AND OPTIONAL EQUIPMENT, BODY AND FRAME,CRUSIS CONTROL.