2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts
none
P164C
2D1D - P164C
100
Information saved in
DME
Fault code
2D1D - P164C
Fault text
Accelerator-pedal module, pedal-position sensor 1, voltage
supply
Fault description
Pedal Position Sensor Potentiometer Supply Channel 1
Electrical
Condition for fault identification
Test condition:
Pedal-position sensor monitor
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry
0.02 sec.
Action in service
1) Check fault memory for problem with throttle valve
and/or main relay, replace main relay as indicated
2) Check power-supply wire for short to ground (also
measure in PWG),
3) Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
CC status report: Reduced engine power!
EML ON restricted PW gradient and PW limit via rpm
DIAGNOSIS AND REPAIR, MAINTENANCE, PARTS AND LABOR, SHOP OPERATIONS, TECHNICIAN'S REFERENCE, DIAGNOSTIC TROUBLE CODES(dtc), RELAYS AND MODULES, SENSORS AND SWITCHES,ENGINE, COOLING AND EXHAUST, POWERTRAIN MANAGEMENT, TRANSMISSION AND DRIVETRAIN, BRAKES AND TRACTION CONTROL, STARTING AND CHARGING, POWER AND GROUND DISTRIBUTION, STEERING AND SUSPENSION, HEATING AND AIR CONDITIONING, RESTRAINTS AND SAFETY SYSTEMS, ACCESSORIES AND OPTIONAL EQUIPMENT, BODY AND FRAME,CRUSIS CONTROL.