2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts
none
P14C6
2F10 - P14C6
Information saved in
DME
Fault code
2F10 - P14C6
Fault text
Radiator blind, bottom
Fault description
Radiator Shutter (Lower) Electrical
Condition for fault identification
Test condition:
1. PKKS must be initialized.
Operation of lower flap:
3 x open and 3 x closed
Or conduct the system test
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
up to 20 sec.
Action in service
1. Check wire from AKKS PIN 4 to PKKS (connection +)
2. Check ground connection to the PKKS
3. Check retention solenoid (internal short or burned
through)
Fault effect and breakdown warning
DIAGNOSIS AND REPAIR, MAINTENANCE, PARTS AND LABOR, SHOP OPERATIONS, TECHNICIAN'S REFERENCE, DIAGNOSTIC TROUBLE CODES(dtc), RELAYS AND MODULES, SENSORS AND SWITCHES,ENGINE, COOLING AND EXHAUST, POWERTRAIN MANAGEMENT, TRANSMISSION AND DRIVETRAIN, BRAKES AND TRACTION CONTROL, STARTING AND CHARGING, POWER AND GROUND DISTRIBUTION, STEERING AND SUSPENSION, HEATING AND AIR CONDITIONING, RESTRAINTS AND SAFETY SYSTEMS, ACCESSORIES AND OPTIONAL EQUIPMENT, BODY AND FRAME,CRUSIS CONTROL.