2010 BMW 128i Convertible (E88) L6-3.0L (N52K) P Code Charts
none
P0041
2C6A - P0041
Information saved in
DME
Fault code
40
2C6A - P0041
Fault text
Oxygen sensors behind catalytic converter, mixed up
Fault description
O2 Sensor Signals Swapped Bank 1 Sensor 2 / Bank 2
Sensor 2
Condition for fault identification
Test condition:
O2 sensor system check
O2 sensor voltage too low = Signal sticks at lean on one
bank and O2 sensor voltage too high = Signal sticks on rich
on the other bank
The trim controller diagnosis must have been executed, see
trim controller diagnosis. Detection of faults during the trim
control diagnosis triggers the active test. Engine running at
idle is adequate for the active test;
Terminal condition: Terminal 15, engine on
Voltage condition:
none
Condition for fault memory entry
Downstream (post-cat) O2 sensor voltage < 0.2 V with rich
lambda specification in active test for one bank, and
downstream (post-cat) O2 sensor voltage > 0.7 V with lean
lambda specification in active test on the other bank
Action in service
Replace downstream (post-cat) O2 sensors
Fault effect and breakdown warning
DIAGNOSIS AND REPAIR, MAINTENANCE, PARTS AND LABOR, SHOP OPERATIONS, TECHNICIAN'S REFERENCE, DIAGNOSTIC TROUBLE CODES(dtc), RELAYS AND MODULES, SENSORS AND SWITCHES,ENGINE, COOLING AND EXHAUST, POWERTRAIN MANAGEMENT, TRANSMISSION AND DRIVETRAIN, BRAKES AND TRACTION CONTROL, STARTING AND CHARGING, POWER AND GROUND DISTRIBUTION, STEERING AND SUSPENSION, HEATING AND AIR CONDITIONING, RESTRAINTS AND SAFETY SYSTEMS, ACCESSORIES AND OPTIONAL EQUIPMENT, BODY AND FRAME,CRUSIS CONTROL.