Saturday, April 18, 2020

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 663


1.3. Perform mechanical inspection of component Y58/1 (Purge control valve).



Figure legend



- 019Vacuum tester



- Y58/1 (Purge control valve)



Test prerequisite



- Actuation is OK.



Test sequence



- Switch off ignition.



- Connect the vacuum tester to the input of component Y58/1 (Purge control valve) with the 3 x distributor.



- Operate engine at idling speed.



- Engine at operating temperature



- Actuate component Y58/1 (Purge control valve), then with key F2.



Warning!Communication with ECU required.



0851



Y58/1 (Purge control valve) : Open circuit / Switchover valve permanently closed (P0444)



Possible cause:



- Y58/1 (Purge control valve)



- N10/1kI (Circuit 87 relay, engine)



- N10/1f57 (Fuse 57)



Affected functions:



- Engine diagnosis



-------------------------------------------------



Test 1: Check power supply of component N3/10 (ME-SFI [ME] control unit).



Test 2: Arrangement of fuses



Test 3: Check component Y58/1 (Purge control valve).