End of test
3.3. Test voltage supply of circuit 87.
Connect socket box to component N3/10 (ME-SFI [ME] control unit).
Figure legend
- A -ConnectionTest cable 35-pin socket box
- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
-
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Test voltage supply of circuit 87.
Test sequence
- Measure direct voltage with multimeter between sockets [ F.2 ] 98 and [F.3] 99 of the 126-pole socket box tester.
- Measure direct voltage with multimeter between sockets [ F.4 ] 100 and [ F.5 ] 101 of the 126-pole socket box tester.
- Measure direct voltage with multimeter between sockets [ F.6 ] 102 and [ F.5 ] 101 of the 126-pole socket box tester.