Friday, November 1, 2019

2010 Mercedes Benz C 300 (204.054) V6-3.0L (272.947) Page 252


Test sequence



- Measure direct voltage with multimeter between sockets (M.80) 80 and (M.44) 44 of the 126-pole socket box tester.



- Switch on ignition.



Specified value



- Voltage[4.8...5.3] V



Question



- Is the measurement value OK?



YES



The measurement value is OK.Possible cause and remedy



- Signal wire



- B70 (Crankshaft Hall sensor)



End of test



NO



The measurement value is not OK.Possible cause and remedy



- Lines to component B70 (Crankshaft Hall sensor)



End of test



0153



Component Y110 (Three-disk thermostat valve) has a short circuit to positive. (P0599)



Possible cause:



- Y110 (Three-disk thermostat valve)



Affected functions:



- Heating



- Engine cooling



-------------------------------------------------



Test 1: Check component Y110 (Three-disk thermostat valve).