YES
The measurement value is OK.Restore original status.
- Plug in the connector 8 at component N93 (Central gateway control unit).
- Switch on ignition.
End of test
NO
The measurement value is not OK.Possible cause and remedy in the case of undervoltage
- Lines between N93 (Central gateway control unit) and
- Lines between N93 (Central gateway control unit) and
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Lines between and
- G1 (Battery)
- G2 (generator)
End of test
1.3.2.1.10. Check power supply at control unit Y3/8n4 (Fully integrated transmission control (VGS) control unit).
Operation number of operation texts and work units or standard texts and flat rates:27-0641Test sequence
- Switch off ignition.
- Separate plug connection at transmission.
- Measure voltage in transmission wiring harness using a multimeter.
- Switch on ignition.
Measure direct voltage with multimeter between 5 and 4Specified value:
- Voltage[8,5...16,4] V
Question
- Is the measurement value OK?