YES
The measurement value is OK.Further possible causes of fault
- Test cable for short circuit to ground.
- Test cable for short circuit to positive.
- Inspect plug connections for corrosion, pinched insulation and loose contact.
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Repair / replace faulty wiring between N118 (Fuel pump control module) and N3/10 (ME-SFI [ME] control unit)
End of test
1.2. Terminal 15 Test control signal for component N118 (Fuel pump control module).
Test sequence
- Switch off ignition.
- Unplug socket A und B from component N118 (Fuel pump control module).
- Measure direct voltage with multimeter between sockets A1 and B5
- Switch on ignition.
- Specified value:11V - 15V
Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Test fuse, replace if necessary
- Inspect plug connections for corrosion, pinched insulation and loose contact.
- N10/1Fuse and relay modules
End of test
2. No further information available.
ED50B
One or more of the signals transmitted by control unit N73 (EIS [EZS] control unit) or N93 (Central gateway control unit) via the CAN bus
are implausible.
Possible cause:
- N73 (EIS [EZS] control unit)
Affected functions:
- CAN Communication
- Automatic transmission Function
-------------------------------------------------
Test 1: Fault in CAN communication with control unit N73 (EIS [EZS] control unit).
1. Fault in CAN communication with control unit N73 (EIS [EZS] control unit).
Operation number of operation texts and work units or standard texts and flat rates:27-0641WARNING
- This is not a function error of control module Y3/8n4 (Fully integrated transmission control (VGS) control unit) and does not justify
replacement.
Possible cause for the entry of this event code
- Operational fault of component N73 (EIS [EZS] control unit)
Possible measures
- Read out fault memory of control unit N73 (EIS [EZS] control unit).